In view of the military present, the source of uninterrupted power supply of 2E brand is a must-have for business and the stable functioning of critical public institutions, in particular, maternity hospitals, laboratories, etc. The model has a power of 6 kW. 2E SD6000 type: online double conversion. UPS of this class provide the most reliable protection of the connected equipment against interruptions in the power grid, which undoubtedly compensates for the costs of its purchase and installation. The operation principle is that the input AC voltage is converted by the rectifier into DC, and then by the inverter – back into AC. Even in the presence of large deviations in the input voltage, 2E UPS continues to supply the connected devices with a pure sinusoidal stabilized voltage. The lack of switching between modes (mains to battery) allows to minimize the risk of damage to «sensitive» equipment. In particular, such UPSs are used for uninterrupted power supply of medical equipment, for data centers and enterprises with a continuous production cycle. The input voltage range is: 110 ~ 176 VAC (linear derating between 50% and 100% load); 176 ~ 288 VAC (no degradation). Input: single-phase three-wire (1F + N + PE). Output: single-phase three-wire (1F + N + PE), in addition, it is possible to adjust the voltage 208/220/230/240 V.

Characteristics
Where to buy
Type Online with double conversion
Installation type Tower
Maximum output power, VA 6000
Effective output power, W 6000
Input Single phase N-PE
Input voltage range, V 110-176 (linear derating between 50% and 100% load), 176-288 (no derating)
Input frequency, Hz 40-70 (automatic detection)
Maximum current, A 1
THD input ≤5%
Output Single phase N-PE
Output voltage range, V 208/220/230/240
Output frequency, Hz 50-60±1% (automatic detection)
THD output ≤1% linear load; ≤4% non-linear load
Inverter overload 105%-110% for 10 min
110%-125% for 1 min
>126%-150% for 30 s
Efficiency ≥ 94% (Mains mode), max. 95% (Battery mode), ≥ 98% (ECO mode)
Sockets Terminal block
Built-in battery 12V/ 7Ah x16
Ability to connect external batteries 12V/ 7Ah x16
Interfaces RS-232, USB, optional SNMP adapter
Display Yes
Typical recharge time (up to 90%), h 9
Noise level, dB ≤55
Operating temperature 0-40 °C
Relative humidity 0-95% (non-condensing)
Colour Black
Protection class IP 20
Protection Overheat protection, fan test protection, overload protection, output short circuit protection, low battery protection
Dimensions (WxDxH), mm 191х495х711
Weight, kg 53
Manufactured China
Warranty 2 years for electronics, 1 year for batteries
Manual
High resolution photo
Drivers&Software

The operating frequency range of 2E SD6000 model is within 40 ~ 70 Hz (automatic detection). The UPS is equipped with sixteen batteries (12 Bt/7 Ah), which restore the charge to 90% in just 9 hours! The charging current (max.) is 1 A. In addition, various RS-232, USB and an optional SNMP adapter are provided. A multi-function LCD display built into the front panel displays the device’s operating status, including error codes.

 

With a weight of 53 kg, the device has dimensions of 191 × 465 × 711 mm. Installation type: TOWER. Noise level – ≤ 55 dB. The product has IP20 protection degree, as well as protection against short circuit, overload, overheating, full battery discharge and fan check ability.