2E OD3000RT UPS, 3000VA/2700W, RT2U, LCD, USB, 3xSchuko 2E-OD3000RT
The war in Ukraine is not abating, the enemy continues to destroy critical infrastructure, in particular the facilities of the country’s energy system. In order to restore the damaged and ensure the stability of the power system, power engineers resort to fan and sometimes emergency shutdowns. Ukrainians understand the proposed measures and are trying to adapt to new realities: they are looking for solutions to provide electricity not only to their own homes, but also to critical public institutions such as hospitals, medical centers, and to meet business needs.
Type | Online with double conversion |
Installation type | Rack/Tower |
Maximum output power, VA | 3000 |
Effective output power, W | 2700 |
Input voltage range, V | 110-176 (linear derating between 50% and 100% load), 176-280 (no derating), 280-300 (50% derating) |
Input frequency, Hz | 40-70 (automatic detection) |
Maximum current, A | 1 |
THD input | ≤6% |
Output voltage range, V | 208/220/230/240 |
Output frequency, Hz | 45-55 or 55-65 (synchronized range); 50-60±0.1 (battery mode) |
THD output | ≤2% linear load; ≤5% non-linear load |
Inverter overload | 105%-125% for 1 min 125%-150% for 30 s >150% for 300 ms |
Efficiency | ≥ 92% (Mains mode), ≥ 87% (Battery mode), ≥ 97% (ECO mode) |
Sockets | 3xSchuko |
Built-in battery | 12V/ 9Ah x6 |
Ability to connect external batteries | 12V/ 9Ah x6 |
Interfaces | RS-232, USB, optional SNMP adapter |
Display | Yes |
Typical recharge time (up to 90%), h | 3 |
Noise level, dB | ≤50 |
Operating temperature | 0-40 °C |
Relative humidity | 0-95% (non-condensing) |
Colour | Black |
Protection class | IP 20 |
Protection | Overheat protection, fan test protection, overload protection, output short circuit protection, low battery protection |
Dimensions (WxDxH), mm | 440х728х88 |
Weight, kg | 30.6 |
Manufactured | China |
Warranty | 2 years for electronics, 1 year for batteries |
The war in Ukraine is not abating, the enemy continues to destroy critical infrastructure, in particular the facilities of the country’s energy system. In order to restore the damaged and ensure the stability of the power system, power engineers resort to fan and sometimes emergency shutdowns. Ukrainians understand the proposed measures and are trying to adapt to new realities: they are looking for solutions to provide electricity not only to their own homes, but also to critical public institutions such as hospitals, medical centers, and to meet business needs.
The operating frequency range of 2E OD3000RT model is within 40 ~ 70 Hz (automatic detection). If the inverter of the device fails or the input current is too high, the bypass mode is automatically activated: the bypass voltage range is -25% ~ +15%. The UPS is equipped with six batteries (12 W/9 Ah), which restore the charge to 90% in just 3 hours! The charging current (max.) is 1 A. In addition, four Schuko sockets, RS-232 connectors, USB and an optional SNMP adapter are provided. An LCD display built into the front panel displays the device’s operating status, including error codes.
With a weight of 30.6 kg, the device has dimensions of 440 × 728 × 88 mm. Installation type: universal (RACK/TOWER). The noise level is 50 dB. The product has IP20 protection degree, as well as protection against short circuit, overload, overheating, full battery discharge and the fan check ability. In case of emergency, users can use the EPO port, which is built into the rear panel, for emergency shutdown of the UPS.